Sistem Scada Level Air Dalam Tangki Menggunakan PLC dan Sensor MPM4700 Intelligent Level Transmitter

Meidi Wani Lestari

Abstract


Controlling the water level in the tank will not be a problem if it is only used for household needs. For example, if the water in the tank reaches the low level limit, you can still wait for the pump to work to be used. In contrast to the needs of water used in industry. For example, the use of water in a tank to supply water to a boiler, or a tank used in a mineral water company and others of the same type can be fatal. The use of HMI in a well-designed process industry can support high performance in an industry to produce a system that is easy to understand visually and also makes it easier for operators to handle troubleshooting problems. The availability of analog input output facilities on the PLC can read the output voltage of the water level sensor module. and display on the HMI diagram in real time

Keywords


PLC, Cx-programmer, NB-Designer, water level control in the tank, HMI

Full Text:

PDF

References


A. S. Nugroho and K. Suryopratomo, “Rancang Bangun Sensor Pengukur Level Interface Air dan Minyak pada Mini Plant Separator,†Teknofisika, vol. 2, no. 2, pp. 43–54, 2013.

Saumi Syahreza, “Rancang Bangun Pengendali OtomatikKetinggianFluida dan TemperaturMenggunakanProgrammableLogic Controller(PLC),†J. Rekayasa Elektr., vol. 9, no. 1, pp. 36–42, 2010.

I. Bayusari, . C., R. Septiadi, and B. Y. Suprapto, “Perancangan Sistem Pemantauan Pengendali Suhu pada Stirred Tank Heater menggunakan Supervisory Control and Data Acquisition (SCADA),†J. Rekayasa Elektr., vol. 10, no. 3, 2013, doi: 10.17529/jre.v10i3.1031.

Antoni Susiono, Handy Wicaksono, and Hany Ferdinando, “Aplikasi Scada System pada Miniatur Water Level Control,†J. Tek. Elektro, vol. 6, no. 1, pp. 37–45, 2006, [Online]. Available: http://puslit2.petra.ac.id/ejournal/index.php/elk/article/view/16435.

T. Pudar and M. Laksono, Sistem Scada Water Level Control Menggunakan Software Wonderware. JURUSAN TEKNIK ELEKTRO FAKULTAS TEKNIK UNIVERSITAS NEGERI SEMARANG, 2013.

P. Shunmugakani, A. A. Selvan, R. V. Ananth, and K. A. Jerome, “Building management system using PLC and SCADA,†J. Chem. Pharm. Sci., vol. 2015-April, no. 5, pp. 328–330, 2015.

I. Systems, “Wonderware FactorySuite InTouch User’s Guide,†Incensys Syst. Inc. All Right Reserv., no. September, 2002.

Microsensor, “MPM4700 Intelligent Level Transmitter,†www.microsensorcorp.com, no. V3, p. [1] “Level Transmitter.†[Online]. Available: http, 2021, [Online]. Available: http://www.flotech.com.sg/products/level/ultrasonic/233-levelwizard-ii.html.

Bagas Adi Luhung, Sumardi, Budi Setiyono (2015), PERANCANGAN SISTEM ANTARMUKA BERBASIS HMI PADA PERANGKAT KERAS PENGEMASAN AIR MINUM , TRANSIENT, VOL.4, NO. 2, ISSN: 2302-9927, 290.

Sudaryana. I. G. S., 2015, PEMANFAATAN RELAI TUNDA WAKTU DAN KONTAKTOR PADA PANEL HUBUNG BAGI (PHB) UNTUK PRAKTEK PENGHASUTAN STARTING MOTOR STAR DELTA, JPTK UNDIKSHA, vol 12 no 2, 131–142




DOI: https://doi.org/10.35334/jbit.v2i1.2739

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.

logo jbit

Address:

Gedung Dekanat, Fakultas Teknik, Universitas Borneo Tarakan. Jl. Amal Lama No. 1, Tarakan, Kalimantan Utara, Indonesia. Kodepos: 77123.
Email: jbit@borneo.ac.id

Creative Commons License

All publications

by JBIT (Jurnal Borneo Informatika dan Teknik Komputer)

are licensed under a
Creative Commons Attribution-NonCommercial 4.0 International License

External Link:
Official Web CE UBT